Review



operator cath volume  (Genovis Inc)


Bioz Verified Symbol Genovis Inc is a verified supplier
Bioz Manufacturer Symbol Genovis Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93

    Structured Review

    Genovis Inc operator cath volume
    Operator Cath Volume, supplied by Genovis Inc, used in various techniques. Bioz Stars score: 93/100, based on 92 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/operator+cath/OpeRATOR+Lyophilized/pmc12485507-120-0-0
    Average 93 stars, based on 92 article reviews
    operator cath volume - by Bioz Stars, 2026-09
    93/100 stars

    Images

    Related Articles

    Biomarker Discovery:

    Article Title: Prolonged Length of Stay After Elective Same-Day Admissions for Pediatric or Congenital Cardiac Catheterizations: A Potential Measure for Procedural Harm
    Article Snippet: .. Total cohort (N = 10,882) Days from procedure to discharge 0-1 d (n = 9845) ≥2 d (n = 1037) Nonmodifiable patient and procedure characteristics Age ≤30 d 63 (1%) 51 (1%) 12 (1%) 1 to 11 mo 1668 (15%) 1371 (14%) 297 (29%) 1 to 17 y 7506 (69%) 6919 (70%) 587 (57%) ≥18 y 1645 (15%) 1504 (15%) 141 (14%) Sex Male 5679 (52%) 5107 (52%) 572 (55%) Female 5086 (47%) 4629 (47%) 457 (44%) Not recorded 117 (1%) 109 (1%) 8 (1%) Diagnosis single ventricle 2487 (23%) 2189 (22%) 298 (29%) Cardiac surgery within 90 d prior 318 (3%) 244 (2%) 74 (7%) Hemodynamic vulnerability score 0 6029 (55%) 5608 (57%) 421 (41%) 1 2345 (22%) 2164 (22%) 181 (17%) 2 1463 (13%) 1237 (13%) 226 (22%) ≥3 1045 (10%) 836 (8%) 209 (20%) PREDIC3T risk category 1 3764 (35%) 3515 (36%) 249 (24%) 2 2632 (24%) 2439 (25%) 193 (19%) 3 1944 (18%) 1720 (17%) 224 (22%) 4 1344 (12%) 1123 (11%) 221 (21%) 5 1198 (11%) 1048 (11%) 150 (14%) Highest severity adverse event None 9567 (88%) 8855 (90%) 712 (69%) Levels 1, 2, or 3a 918 (8%) 753 (8%) 165 (16%) Levels 3bc, 4, or 5 397 (4%) 237 (2%) 160 (15%) Potentially modifiable data Fellow present 908 (8%) 802 (8%) 106 (10%) Cath procedure time above threshold Yes 1752 (16%) 1517 (15%) 235 (23%) No 8237 (76%) 7504 (76%) 733 (71%) Not recorded 893 (8%) 824 (8%) 69 (7%) Contrast used >6 mL/kg Yes 1148 (11%) 910 (9%) 238 (23%) No 8872 (82%) 8113 (82%) 759 (73%) Not recorded 862 (8%) 822 (8%) 40 (4%) Airway management Intubated or trach from the start 9723 (89%) 8780 (89%) 943 (91%) Other 1107 (10%) 1024 (10%) 83 (8%) Not recorded 52 (1%) 41 (<1%) 11 (1%) Sedation General anesthesia 10,081 (93%) 9103 (92%) 978 (94%) Other 738 (7%) 689 (7%) 49 (5%) Not recorded 63 (1%) 53 (1%) 10 (1%) Operator years since training <5 y 2787 (26%) 2434 (25%) 353 (34%) 5-24 y 6372 (58%) 5895 (60%) 477 (46%) ≥25 y 1723 (16%) 1516 (15%) 207 (20%) Operator cath volume <100 cases/y 1945 (18%) 1784 (18%) 161 (16%) 100-200 cases/y 3984 (37%) 3710 (38%) 274 (26%) >200 cases/y 4953 (45%) 4351 (44%) 602 (58%) Institutional differences Free-standing children’s hospital 10,333 (95%) 9335 (95%) 998 (96%) Hospital cath volume <250 cases/y 1564 (14%) 1434 (15%) 130 (12%) 250-400 cases/y 3849 (35%) 3532 (36%) 317 (31%) >400 cases/y 5469 (50%) 4879 (50%) 590 (57%) Values are n (%). ..

    Article Title: Prolonged Length of Stay After Elective Same-Day Admissions for Pediatric or Congenital Cardiac Catheterizations: A Potential Measure for Procedural Harm
    Article Snippet: .. Odds ratio 95% CI P value Age at catheterization <1 y 2.29 1.9-2.8 <.001 Diagnosis single ventricle 1.48 1.2-1.8 <.001 Cardiac surgery within 90 d prior 1.31 0.99-1.7 .057 Hemodynamic vulnerability score (vs 0) 1 1.19 0.97-1.5 .094 2 1.79 1.4-2.3 <.001 ≥3 2.43 1.7-3.4 <.001 PREDIC3T risk category (vs 1) 2 0.80 0.64-1.0 .051 3 1.30 1.0-1.6 .028 4 1.57 1.2-2.1 .002 5 1.48 1.1-2.1 .023 Any levels 3bc, 4, or 5 AE 5.93 4.6-7.6 <.001 Cath procedure time above threshold 1.53 1.2-1.9 <.001 Contrast used >6 mL/kg 1.28 1.0-1.6 .021 Operator years since training (vs 5-24) <5 y 1.51 1.2-2.00 .003 ≥25 y 1.68 1.3-2.1 <.001 Operator cath volume (vs 100-200) <100 cases/y 1.18 0.83-1.7 .37 >200 cases/y 1.71 1.2-2.4 .003 Odds ratios and 95% CIs are estimated from GEE models which cluster on the operator. ..

    Article Title: Prolonged Length of Stay After Elective Same-Day Admissions for Pediatric or Congenital Cardiac Catheterizations: A Potential Measure for Procedural Harm
    Article Snippet: .. Odds ratio 95% CI P value Age at catheterization <1 y 2.5 2.1-3.0 <.001 Sex Male 1.1 0.99-1.3 .067 Not recorded 0.7 0.35-1.6 .44 Diagnosis single ventricle 1.4 1.2-1.6 <.001 Cardiac surgery within 90 d prior 3.0 2.2-4.1 <.001 Hemodynamic vulnerability score (vs 0) 1 1.1 0.93-1.3 .24 2 2.4 2.0-3.0 <.001 ≥3 3.3 2.6-4.4 <.001 PREDIC3T risk category (vs 1) 2 1.1 0.90-1.4 .31 3 1.8 1.5-2.3 <.001 4 2.8 2.2-3.6 <.001 5 2.0 1.5-2.8 <.001 Any levels 3bc, 4, or 5 AE 7.4 5.9-9.3 <.001 Fellow present 1.3 0.91-1.8 .15 Cath procedure time above threshold (vs no) Yes 1.6 1.2-2.0 <.001 Cath procedure time not recorded 0.9 0.62-1.2 .35 Contrast used >6 mL/kg (vs no) Yes 2.8 2.3-3.4 <.001 Contrast not recorded 0.5 0.36-0.8 <.001 Airway management (vs other) Intubated or tracheostomy 1.3 0.99-1.8 .061 Not recorded 3.3 1.6-6.7 <.001 Sedation (vs other) General anesthesia 1.5 1.1-2.1 .016 Not recorded 2.7 1.4-4.9 .002 Operator years since training (vs 5-24) <5 y 1.8 1.2-2.7 .005 ≥25 y 1.7 1.0-2.8 .041 Operator cath volume (vs 100-200) <100 cases/y 1.2 0.85-1.8 .28 >200 cases/y 1.9 1.2-2.8 .003 Free-standing children’s hospital 1.4 0.97-2.0 .072 Hospital cath volume (vs 250-400) <250 cases/y 1.0 0.67-1.5 .96 >400 cases/y 1.4 0.88-2.1 .17 Odds ratios and 95% CIs are estimated from GEE models which cluster on the operator. ..



    Similar Products

    93
    Genovis Inc operator cath volume
    Operator Cath Volume, supplied by Genovis Inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/operator+cath/OpeRATOR+Lyophilized/pmc12485507-120-0-0
    Average 93 stars, based on 1 article reviews
    operator cath volume - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    93
    Genovis Inc operator cath
    Operator Cath, supplied by Genovis Inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/operator+cath/OpeRATOR+Lyophilized/10__1016_slash_j__jscai__2025__103804-104-171-171
    Average 93 stars, based on 1 article reviews
    operator cath - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    Image Search Results